Nikon NEXIV-VMR-3020 Nikon Vision System Stage Stroke (Xx Yy Zz) (Standard) 300 x 200 x 150 mm (11.8 x 7.9x 5.9) in. Minimum readout 0.1 microns Maximum work piece weight 20kg (44.0 lb.) Measuring accuracy at 20C+/-0.5K: U1x U1y : 1.5 + 4L/1000 microns Z-

Item number:
NEXIV-VMR-3020
Details
Additional Details Stage Stroke (Xx Yy Zz) (Standard): = 300 x 200 x 150 mm (11.8 x 7.9x 5.9) in.|Minimum readout: = 0.1 microns|Maximum work piece weight: = 20kg (44.0 lb.)|Measuring accuracy at 20C+/-0.5K: U1x U1y = 1.5 + 4L/1000 microns|Z-axis guide accuracy: = (1.5+L/150) microns|
Nikon NEXIV-VMR-10080 NEXIV VMR-10080 Automated Measuring System Stage Stroke (Xx Yy Zz) (Standard) 1000 x 800 x 150mm Measuring Accuracy U1 XY : (3.5 +L/200) Measuring Z Axis : (3 + L/50)

Nikon NEXIV-VMR-10080 NEXIV VMR-10080 Automated Measuring System Stage Stroke (Xx Yy Zz) (Standard) 1000 x 800 x 150mm Measuring Accuracy U1 XY : (3.5 +L/200) Measuring Z Axis : (3 + L/50)

Nikon NEXIV-VMR-6555 Nikon Vision System Stage Stroke (Xx Yy Zz) Standard 650 x 550 x 150 mm (25.6 x 21.7x 5.9) in. Minimum readout 0.1 microns  Maximum work piece weight 30kg (66.1lb.)  Measuring accuracy at 20C+/-0.5K: U1x U1y : 1.5 + 4L/1000 microns  Z

Nikon NEXIV-VMR-6555 Nikon Vision System Stage Stroke (Xx Yy Zz) Standard 650 x 550 x 150 mm (25.6 x 21.7x 5.9) in. Minimum readout 0.1 microns Maximum work piece weight 30kg (66.1lb.) Measuring accuracy at 20C+/-0.5K: U1x U1y : 1.5 + 4L/1000 microns Z

Nikon NEXIV-VMR-3020 Nikon Vision System Stage Stroke (Xx Yy Zz) (Standard) 300 x 200 x 150 mm (11.8 x 7.9x 5.9) in. Minimum readout 0.1 microns Maximum work piece weight 20kg (44.0 lb.) Measuring accuracy at 20C+/-0.5K: U1x U1y : 1.5 + 4L/1000 microns Z-

Availability: In stock
Item number
NEXIV-VMR-3020
Nikon Vision System
Four models with 5 step zoom magnification to cover different fields of view and resolution requirements. VMR3020 is fast accurate and durable - 300 X 200Y mm travel cast Mehanite stage with 150mm Z . Precision ground large diameter ballscrew with DC servo motors for high speed and stiffness. Improved stage acuracy with new lower coefficient of expansion 0.1 micron resolution scales. Advanced Nikon optics provide superior images for improved repeatability and accuracy.
Telecentric 15:1 zoom module with 0.35 N.A objective and 50mm free working distance.
Vision and TTL Laser autofocus. High speed Throuogh-The-Lens Laser scans 1000 points/sec.with 0.5 um Z accuracy at 2 sigma.
Advanced image processing enhances contrast and fidelity with powerful edge detection to insure accuracy and repeatability.
New easy to program versatile VMR Automeasure software includes: CAD reader Offline programing Profiling software and Programing wizards.
Faster image acquisition and system speed with selected defect-free instrument grade progressive scan black & white CCD camera.
Programable dual white LED illuminator rings


Stage Stroke (Xx Yy Zz) (Standard): 300 x 200 x 150 mm (11.8 x 7.9x 5.9) in.
Minimum readout: 0.1 microns
Maximum work piece weight: 20kg (44.0 lb.)
Camera: B/W Progressive Scan camera or colour CCD camera
Maximum specimen height (Standard): 150mm
Objective Working Distance: Type 123=50mm z120x=hi mag. 9.8mm low mag. 32mm
Zoom Head Magnification and Field of View: Type 1: 0.5- 7.5x 9.33 x 7.00mm - 0.622 x 0.467; Type 2: 1- 15x 4.67 x 3.50mm - 0.311x 0.233mm; Type 3: 2 - 30x 2.33 x 1.75mm - 0.155 x 0.117mm
Auto Focus: (TTL)Through the lens laser and video auto focus
Power Source: AC 100 to 240 V+/- 10% 50/60 Hz
Power Consumption: Approximately 7A

Dimensions and Weight:
Main Body Only: 500(W) x 690(D) x 1195(H) mm 160kg; 19.7(W) x 27.2(D) x 47(H) in. 352.7lb
Main Body & Table: 690(W) x 730(D) x 1725(H) mm 200kg; 27.2(W) x 28.8(D) x 67.9(H) in. 440.9lb
Controller: 250(W) x 550(D) x 500(H) mm 20kg; 9.8(W) x 21.7(D) x 19.7(H) in. 44.1lb
Foot Print: 2100(W) x 1100(D) mm; 82.7(W) x 43.3(D) in.
Host Computer:
Main unit: IBM PC/AT compatible (Windows(R) 2000)
Monitor: 19-inch LCD flat panel

Measuring accuracy at 20C+/-0.5K: U1x U1y: 1.5 + 4L/1000 microns U2xy (Standard): 2.5 + 4L/1000 microns Z-axis guide accuracy: (1.5+L/150) microns