Nikon VMR-1515-PERFORMA Nikon Vision System Stage Stroke (Xx Yy Zz) (Standard) 150 x 150 x 150 mm (5.9 x 5.9x 5.9) in. Minimum readout 0.1 microns Maximum work piece weight 20kg (44.0 lb.) Measuring accuracy at 20C+/-0.5K: U1x U1y 1.5 + 4L/1000 microns Z-

Item number:
VMR-1515-PERFORMA
Details
Additional Details Stage Stroke (Xx Yy Zz) (Standard): = 150 x 150 x 150 mm (5.9 x 5.9x 5.9) in.|Minimum readout: = 0.1 microns|Maximum work piece weight: = 20kg (44.0 lb.)|Measuring accuracy at 20C+/-0.5K: U1x U1y: = 1.5 + 4L/1000 microns|Z-axis guide accuracy: = (1.5 + L/150) microns|
Nikon VMR-1515 Nikon Vision System Stage Stroke (Xx Yy Zz) (Standard) 150 x 150 x 150 mm (5.9 x 5.9x 5.9) in. Minimum readout  0.1 microns Maximum work piece weight 20kg (44.0 lb.) Measuring accuracy at 20C+/-0.5K:  U1x U1y 1.5 + 4L/1000 microns Z-axis gu

Nikon VMR-1515 Nikon Vision System Stage Stroke (Xx Yy Zz) (Standard) 150 x 150 x 150 mm (5.9 x 5.9x 5.9) in. Minimum readout 0.1 microns Maximum work piece weight 20kg (44.0 lb.) Measuring accuracy at 20C+/-0.5K: U1x U1y 1.5 + 4L/1000 microns Z-axis gu

Nikon VMR-H3030 NEXIV High Accuracy Edition Series VMR-H3030  Stroke (X x Y x Z): Standard- : 300 x 300 x 150 mm (11.8 x 11.8 x 5.9 in.) Measuring accuracy (X . Y): Standard U1XY - ; : High Magnification U2XY (0.9 + L/300) microns; U1XY (0.6 + L/300) ) mi

Nikon VMR-H3030 NEXIV High Accuracy Edition Series VMR-H3030 Stroke (X x Y x Z): Standard- : 300 x 300 x 150 mm (11.8 x 11.8 x 5.9 in.) Measuring accuracy (X . Y): Standard U1XY - ; : High Magnification U2XY (0.9 + L/300) microns; U1XY (0.6 + L/300) ) mi

Nikon VMR-1515-PERFORMA Nikon Vision System Stage Stroke (Xx Yy Zz) (Standard) 150 x 150 x 150 mm (5.9 x 5.9x 5.9) in. Minimum readout 0.1 microns Maximum work piece weight 20kg (44.0 lb.) Measuring accuracy at 20C+/-0.5K: U1x U1y 1.5 + 4L/1000 microns Z-

Availability: In stock
Item number
VMR-1515-PERFORMA
NEXIV VMR 1515 PERFORMA
Our most economical model: 6 x 6 travel and Lower Cost than VMR1515 with all the same features except laser AF & 2d ring illuminator.
Three models with 5-step zoom magnification to cover different fields of view and resolution requirements.
VMR1515 is fast accurate and durable - 150 X 150 Y mm travel cast Mehanite stage with 150mm Z.
Precision ground large diameter ball screw with DC servo motors for high speed and stiffness.
Improved stage accuracy with new lower coefficient of expansion 0.1 micron resolution scales.
Advanced Nikon optics provide superior images for improved repeatability and accuracy.
Telecentric 15:1 zoom module with 0.35 N.A. objective and 50mm free working distance.
Vision autofocus. High speed.
Advanced image processing enhances contrast and fidelity with powerful edge detection to ensure accuracy and repeatability.
New easy-to-program versatile VMR Automeasure software includes: CAD reader offline programming profiling software and programming wizards.
Faster image acquisition and system speed with selected defect-free instrument grade progressive scan black and white CCD camera.
Programmable single white LED illuminator ring.


Stage Stroke (Xx Yy Zz) (Standard): 150 x 150 x 150 mm (5.9 x 5.9x 5.9) in.
Minimum readout: 0.1 microns
Maximum work piece weight: 20kg (44.0 lb.)
Camera: B/W progressive scan camera
Maximum specimen height (Standard): 150mm
Objective Working Distance: models: Type 1 2 3 = 50mm
Zoom Head Magnification and Field of View: Type 1: 0.5- 7.5x 9.33 x 7.00mm - 0.622 x 0.467; Type 2: 1- 15x 4.67 x 3.50mm - 0.311x 0.233mm; Type 3: 2 - 30x 2.33 x 1.75mm - 0.155 x 0.117mm
Auto Focus: "TTL" Through the lens video auto focus
Power Source: AC 100 to 240 V+/- 10% 50/60 Hz
Power Consumption: Approximately 7A
Footprint: 2100(W) x 1100(D) mm; 82.7(W) x 43.3(D) in.

Measuring accuracy at 20C+/-0.5K: U1x U1y: 1.5 + 4L/1000 microns
Measuring accuracy at 20C+/-0.5K: U2xy (Standard): 2.5 + 4L/1000 microns
Z-axis guide accuracy: (1.5 + L/150) microns