Temperature & Humidity
Data Logger
GSM-100E/700ETemp. GSM-200E Temp. &HumidityDESCRIPTION:
GSM series data loggers are used to measured and recorded
temperature and for wireless network platforms. Sending and
receiving mobile phone messages is one of the distinctive features
of this series of instruments. GSM series data loggers are with professional PC software and
mobile APP. Users can configure the functions and parameters of
the instrument through the PC software or mobile phone APP, and
can also use the mobile phone APP to view data in real time and
manage messages. Users only need to connect the instrument (via
USB) to the computer, then it will directly generate the report
without additional software. Users can also export the report in
multiple formats through PC software. GSM-100E is using the normal temperature probe, the
measuring range of its internal probe is -30~+65℃, and external
probe is -40~+125℃. On the basic of GSM-100E, GSM-200E added the humidify
measuring function. Therefore it needs to be used with an external
temperature and humidity probe. Therefore it needs to be used
with an external temperature and humidity probe. On the basic of GSM-100E, GSM-700E optimized its principle, and increased the measuring range of the external probe. The
measuring range of its internal temperature probe is -30~+65℃, and its external temperature probe is increased to -200~+250℃.
FEATURES: • Sending and receiving mobilephonemessages • Can connect with 3 mobile numbersatthe same time
• With Mobile Phone APP
• With PC software
• Storage capacity is up to 500000readings• Display max, min and average• Multiple probes optional • Measuring interval is optional from10secto 18 hours • Support report format of txt/csv/xls/dlg• Protection class IP65
• Long standby time
• Multiple selections of power supply• Data anti-lost when power off • Battery protection
Model GSM-100E GSM-200E
Measuring parameter Temperature Temperature, Humidity
Probe type Internal, External External
Unit ℃, ℉ Temperature: ℃, ℉; Humidity: %RHMeasuring range of the
whole machine
Internal: -30~+65℃
External: -40~+125℃
External: -40~+125℃0~100%RH
Measuring accuracy of
the whole machine
±0.2℃(0~+65℃)
The rest of the range is shown in Figure 1 below
Temperature: ±0.2℃(0~+65℃)
The rest of the range is shown inFigure1belowHumidity: ±3%RH(10~90%RH, 25℃)
±4%RH(others)
Resolution 0.1℃ Temperature: 0.1℃; Humidity: 0.1%RHStorage capacity 25920 or 500000 readings(Software optional)
Response time (t90) 15 min(Internal Probe); 5 min(External Probe)
Measuring interval 5 sec
Display refresh interval 5 sec
Display Segment LCD
Operation temperature -10℃~+50℃(Non-condensing)
Storage temperature -20℃~+60℃(Without battery)
Power supply 4 pcs AA 1.5V alkaline batteries; USB 5V/2A
Battery life
About 1 year(Condition: Battery capacity 2000mAh, operation temperature 25℃, thenumberofmessages will not be sent over 12 per day)
Protection class IP65
Dimensions 109*96*35mm
Material ABS
Weight About 130g(Not including battery and probe)
Warranty 12 month